Juan Jose Fuentes-Alzate*1, Edgard Augusto Fuentes Torrado2, Juan Pablo Alzate Granados3
Juan Jose Fuentes-Alzate1*, Edgard Augusto Fuentes Torrado2 and Juan Pablo Alzate Granados3
1Departamento de Médicos Generales, Universidad Javeriana, Bogotá D.C. Colombia
2Departamento de Anestesiólogo, Universidad del Bosque y Universidad de la Sabana Medicina, Bogotá D.C Colombia
3Departamento de Epidemiólogo, Universidad Nacional, Bogotá D.C. Colombia
Fecha de recepción: Julio 24, 2021, Fecha de aceptación: Noviembre 11, 2021, Fecha de publicación: Noviembre 18, 2021
Liposuction and tummy tuck are two of the most performed cosmetic surgeries in the world. One of the most frequent complications of these procedures is perioperative bleeding, which can lead to inappropriate postoperative procedures with greater complications. For this reason, new methods must be sought to reduce blood loss in this type of surgery.
Keywords
Tranexamic acid; liposuction; abdominoplasty; hemorrhage
Liposuction and abdominoplasty are two of the most performed cosmetic procedures in Colombia and worldwide. The International Society for Aesthetic Plastic Surgery (ISAPS) estimates that in 2018 1,732,620 liposuctions and 888,712 tummy tucks were performed in the world [1]. Beyond that, in Colombia 273,316 cosmetic surgical procedures were performed, of which 17.1% corresponded to liposuction and 8.5% corresponded to abdominoplasty [1].
One of the main complications of these cosmetic procedures is bleeding, which if not controlled can lead to inappropriate postoperative procedures or even death (2). Regarding the pathophysiology of bleeding during this type of surgical procedure, it is known that when performing liposuction with suction cannulas, blood vessels and adjacent tissue are injured, which causes bleeding [2]. Samdal et al propose 3 ways by which the blood that was extravasated due to the damage to the tissues and blood vessels is lost: An external loss in the lipoaspirate, an internal loss due to the formation of dead space when removing fat and blood that It is found in instruments used in surgery such as gauze or compresses [3].
Over the years, new methods have been sought to reduce blood loss since liposuction is one of the most performed cosmetic surgeries and perioperative bleeding is one of its main complications. For this reason, in 1985 the dermatologist Jeffrey Klein developed the tumescent liposuction technique in which adipose tissue is infiltrated with a solution composed of lidocaine, epinephrine and large amounts of saline solution (called Klein's solution) [4]. Later it was shown that this technique reduced the amount of bleeding compared to other techniques, such as dry liposuction [4].
Likewise, over the years, new possibilities have emerged that contribute even more to reducing postoperative bleeding such as tranexamic acid. This drug is an antifibrinolytic agent that inhibits the conversion of plasminogen to plasmin, which prevents fibrin degradation and preserves the clot structure [5]. Due to this mechanism of action, tranexamic acid could be useful to reduce bleeding, since it would act in conjunction with Klein's solution to reduce blood extravasation.
When reviewing the literature on the use of tranexamic acid in plastic surgery (Medline and Scielo), the evidence is scarce and the articles that were found expose the benefits of this drug in the management of burns, maxillofacial surgery and otorhinolaryngology.
For this reason, it was decided to carry out a descriptive study with the objective of evaluating postoperative bleeding and the need for transfusion in patients who received tranexamic acid during liposuction and abdominoplasty.
A retrospective case series report was carried out with the objective of evaluating the effectiveness of tranexamic acid in reducing perioperative bleeding in female patients who underwent abdominoplasty plus liposuction.
Population
For the case report, they reviewed the medical records of the patients who underwent surgery at the “Santa Barbara Surgical Center” clinic in the city of Bogotá between 01/15/2020 until 03/15/2020. For the study, those patients who underwent abdominoplasty plus body liposuction were included. Patients who underwent an additional procedure were excluded from the study.
|
Inclusion criteria |
Exclusion criteria |
|---|---|
|
Surgery performed: Abdominoplasty + Liposuction |
Hypersensitivity to tranexamic acid |
|
Age: 18 - 65 |
Presence of coagulation diseases |
|
Tranexamic acid application |
Abdominoplasty + Liposuction + Other procedure |
| ASA I or II patients |
Male |
Table 1: Eligibility criteria.excel
By having a population of patients who underwent only the two aforementioned procedures, the inclusion criteria were applied (see Table 1). Patients with clotting diseases that increase the risk of bleeding such as some type of hemophilia, Von Willebrand disease, protein C or S deficiencies were excluded from the study. Similarly, only patients were included in whom the application of 1 g of tranexamic acid during anesthetic induction was reported.
After applying the inclusion and exclusion criteria, a population of 37 female patients was obtained, within the age range between 18 and 65 years, who had no history of coagulation diseases and who only underwent abdominoplasty plus liposuction.
Once the total number of cases to be reported was counted, it was decided to compare the blood count that was taken prior to surgery and with a blood count that was taken 12 hours after the procedure. Additionally, the weight of the flap that was resected in the lipectomy, the fluids that were infiltrated for liposuction, and the fluids that were suctioned were reviewed.
The procedures were performed by a certified team made up of 1 anesthesiologist, 1 plastic surgeon, 1 surgical instrumenter, and 1 nursing assistant. Additionally, prior to surgery, acute normovolemic hemodilution was performed in all patients with 500 cc of blood, which was replaced with 500 cc of crystalloids in the first hour of surgery. Anesthetic induction was performed as follows: Cisatracurium 0.15 mg / kg as a neuromuscular relaxant, Midazolam 0.05 mg / kg as an inducer together with Fentanyl of 1-2 mcg / kg, Lidocaine 1mg / kg and Propofol 1-2 mg / kg. Maintenance of anesthesia was performed with Remifentanil 0.15 to 0.2 mcg / kg / min and Sevorane at 1 MAC.
Sample size
Due to the descriptive nature of the work, no formal sample size calculation was performed.
Statistical analysis
Quantitative variables are presented in the form of means and standard deviations, while qualitative variables are presented in the form of proportions and absolute numbers. In an exploratory way, a Wilcoxon rank test of related data was performed to evaluate the differences before and after hemoglobin (Hb) and hematocrit (Ht).
Finally, an exploratory Spearman correlation was performed to evaluate the correlation between hemoglobin delta and hematocrit delta with flap weight.
Ethical considerations
The institution where these procedures were performed is certified by the Bogotá Health Secretariat and all patients who participated in the study have a duly completed consent prior to performing the procedure.
Based on what is mentioned in resolution 8430 of 1993, we consider that the study carried out is a low-risk investigation since it seeks to report a series of cases [6].
On the other hand, being a retrospective study, the population of our study was taken as passive subjects who had no knowledge about the research to be carried out. Given this, it was decided to comment with the directors of the clinic who authorized it to be carried out (minutes of 03/13/20) taking into account the current regulations on the use of personal data. Data collection was supervised by the clinic's information and registry coordinator, in order to ensure the confidentiality and protection of personal data of the patients who participated in the study.
Results
The results obtained in the study can be viewed in Tables 2 and 3 (at the end of the text).
| Average | Minimum value | Maximum value | |
|---|---|---|---|
| Age (years) | 39.79 | 26 | 46 |
| Hb prequirúrgica (g/dl) | 13.91 | 10.5 | 16.1 |
| Hb prequirúrgica (g/dl) | 42.08 | 25.6 | 47 |
| Hb post quirúrgico (g/dl) | 10.81 | 8.2 | 13 |
| Post-surgical Ht (%) | 33.08 | 25.2 | 38.4 |
| Infiltrated liquids (cc) | 4972.97 | 2300 | 9000 |
| Suctioned liquids (cc) | 4356.75 | 1700 | 7500 |
| Flap weight (gr) | 858.37 | 200 | 3540 |
| Delta Hb | 3.1 | - | - |
| And l and others and H | 8.99 | - | - |
Table 2: Summary of results excel
The age of the patients who participated in the study was first compared. It was determined that the mean age of the patients was 39.7 years. The youngest patient in the study was 24 years old and the oldest patient was 64 years old.
By looking at the pre and post surgical blood counts, several results can be obtained. The average pre hemoglobin was 13.9 g / dl and the pre hematocrit was 42.1%, while the average post hemoglobin was 10.8 g / dl and the post hematocrit was 33.1%.
Taking the values of the pre and post hemograms, it was possible to determine the delta of the change in hemoglobin and hematocrit for each of the patients. The mean hemoglobin delta was 3.1 g / dl while the hematocrit delta was 8.99%.
In only one patient, Hb was less than 12 g / dl prior to the procedure. No patient in the study had a post-procedure Hb lower than 8 g / dl. The lowest Hb value found after the procedure was 8.2 g / dl. Likewise, no patient in the study required a red blood cell transfusion after the procedure.
The infiltrated and suctioned fluids were then compared. The average amount of liquids used for infiltration was 4972.9 cc of Klein's solution. On the other hand, the average amount of fluid suctioned during liposuction was 4356.7 cc. Regarding the fluid balance between infiltrated and suctioned fluids, it was evidenced that in 9 patients it had a negative value (which meant that more fluids were suctioned), while in 27 patients the balance had a positive value (which meant that they were infiltrated more fluids) and only 1 patient had a balance of 0 (sucked fluids were equal to infiltrated fluids).
Additionally, the weights of the flaps were compared. The average weight of the resected flap during abdominoplasty was 858.3 grams. The resected flap with the highest weight was 3540 grams, while the flap with the lowest weight was 200 grams.
Taking these data mentioned, it was decided to perform a Spearman correlation between post-surgical hemoglobin and suctioned fluids, which was 0.056. This means that there is no direct correlation between these variables. Likewise, a correlation was made between the post-surgical hematocrit and the sucked fluids, which was -0.022, so there is no association and a correlation between the hemoglobin delta and the sucked fluids, which was 0.05, so neither there was association.
Age was also not correlated with post-surgical hemoglobin, since it presents an index of -0.23, so there was no association.
Finally, it was decided to make a correlation between the weight of the flap and other study variables. The correlation between flap weight and post-surgical hemoglobin was -0.16, so there was no association. Similarly, a correlation was made between the weight of the flap and the hemoglobin delta, which had a coefficient of 0.046, so there was no association (the data presented in the Spearman correlation can be viewed in Table 3).
| patient age | Hb pre | Hto pre | Hb post | Hto post | infiltrators | sucked | flap | Delta Hb | Delta Hto | Balance liquids |
|---|---|---|---|---|---|---|---|---|---|---|
| 33 | 14,8 | 45,3 | 11,6 | 34,9 | 3500 | 3700 | 380 | 3,2 | 10,4 | -200 |
| 31 | 13,4 | 40,7 | 11,5 | 33,2 | 5000 | 4800 | 800 | 1,9 | 7,5 | 200 |
| 40 | 14,7 | 43,2 | 11,9 | 35,3 | 9000 | 7100 | 560 | 2,8 | 7,9 | 1900 |
| 47 | 13 | 39 | 13 | 38 | 4500 | 3600 | 430 | 0 | 1 | 900 |
| 45 | 15,3 | 46,8 | 10,9 | 34,4 | 5000 | 3000 | 1100 | 4,4 | 12,4 | 2000 |
| 39 | 13 | 39 | 11,1 | 35 | 3500 | 3500 | 450 | 1,9 | 4 | 0 |
| 53 | 12 | 38 | 11,1 | 36,6 | 7000 | 4800 | 720 | 0,9 | 1,4 | 2200 |
| 34 | 14,1 | 42,9 | 11,3 | 34,1 | 3500 | 3100 | 460 | 2,8 | 8,8 | 400 |
| 26 | 13,6 | 42,6 | 10,7 | 32.9 | 4000 | 3000 | 300 | 2,9 | 9,7 | 1000 |
| 56 | 14,1 | 43,4 | 9,8 | 31,4 | 2500 | 1700 | 300 | 4,3 | 12 | 800 |
| 45 | 14,2 | 44,5 | 9,6 | 28,4 | 4000 | 4500 | 250 | 4,6 | 16,1 | -500 |
| 45 | 12,1 | 25,6 | 8,8 | 26,7 | 4800 | 4600 | 1170 | 3,3 | -1,1 | 200 |
| 39 | 13,8 | 40,4 | 11,9 | 35 | 6000 | 4900 | 290 | 1,9 | 5,4 | 1100 |
| 41 | 13,5 | 43,1 | 10,2 | 30,9 | 7000 | 6600 | 2640 | 3,3 | 12,2 | 400 |
| 33 | 14,8 | 45,3 | 11,6 | 34,9 | 3000 | 3600 | 680 | 3,2 | 10,4 | -600 |
| 42 | 13,1 | 38,4 | 11,6 | 37,7 | 6500 | 5900 | 340 | 1,5 | 0,7 | 600 |
| 44 | 14,4 | 42,2 | 10 | 31,2 | 5500 | 3300 | 200 | 4,4 | 11 | 2200 |
| 34 | 14,1 | 42,9 | 11,3 | 34,1 | 4500 | 4000 | 500 | 2,8 | 8,8 | 500 |
| 45 | 15,3 | 45,3 | 12 | 35,8 | 4800 | 4750 | 1220 | 3,3 | 9,5 | 50 |
| 42 | 15,1 | 43,7 | 12,8 | 38,4 | 5000 | 4800 | 480 | 2,3 | 5,3 | 200 |
| 39 | 15,5 | 44,1 | 10,9 | 33,3 | 3800 | 5300 | 900 | 4,6 | 10,8 | -1500 |
| 40 | 14,7 | 45,5 | 10,8 | 32,9 | 3600 | 3800 | 280 | 3,9 | 12,6 | -200 |
| 31 | 14,7 | 43,4 | 11,3 | 35,4 | 5000 | 5100 | 200 | 3,4 | 8 | -100 |
| 37 | 14,3 | 46,3 | 10 | 30 | 2300 | 2000 | 460 | 4,3 | 16,3 | 300 |
| 42 | 13,8 | 41,4 | 10,5 | 32,7 | 4000 | 4500 | 1600 | 3,3 | 8,7 | -500 |
| 44 | 16,1 | 46,8 | 11,3 | 36,4 | 6000 | 4600 | 1100 | 4,8 | 10,4 | 1400 |
| 32 | 13,4 | 38,9 | 10,3 | 30,6 | 7000 | 6000 | 3540 | 3,1 | 8,3 | 1000 |
| 34 | 15,1 | 45,2 | 11,8 | 36,9 | 5000 | 4200 | 900 | 3,3 | 8,3 | 200 |
| 31 | 15,2 | 47 | 10,4 | 30,3 | 6000 | 6100 | 990 | 4,8 | 16,7 | -100 |
| 37 | 14,7 | 42,8 | 10,7 | 30,3 | 5000 | 7500 | 1450 | 4 | 12,5 | -2500 |
| 30 | 13,5 | 41,2 | 11,4 | 34,5 | 5000 | 2200 | 1100 | 2,1 | 6,7 | 2800 |
| 32 | 13,8 | 43,3 | 12,3 | 38, | 6000 | 4300 | 1100 | 1,5 | 5,1 | 1700 |
| 47 | 10,5 | 34,6 | 8,4 | 27,2 | 6000 | 4700 | 1130 | 2,1 | 7,4 | 1300 |
| 45 | 13,2 | 40,4 | 8,2 | 25,6 | 5700 | 4950 | 1020 | 5 | 14,8 | 750 |
| 38 | 12,5 | 39,7 | 8,2 | 25,2 | 5000 | 4600 | 840 | 4,3 | 14,5 | 400 |
| 64 | 13,5 | 47 | 10,5 | 34 | 5000 | 2500 | 700 | 3 | 13 | 2500 |
| 33 | 12,1 | 37,1 | 10,5 | 31,8 | 5000 | 3600 | 1180 | 1,6 | 5,3 | 1400 |
Table 3: Patient data.excel
|
|
age |
Hb pre |
Hto pre |
Hb post |
Hto post |
infiltrators© |
sucked |
flap |
â??Hb |
â??Hto |
|---|---|---|---|---|---|---|---|---|---|---|
|
age |
1,000 |
|
|
|
|
|
|
|
|
|
|
Hb pre |
-0,1419 |
1,000 |
|
|
|
|
|
|
|
|
|
Hto pre |
-0,0471 |
0,8434 |
1,000 |
|
|
|
|
|
|
|
|
Hb post |
-0,2335 |
0,3295 |
0,1674 |
1,000 |
|
|
|
|
|
|
|
Hto post |
-0,0397 |
0,2667 |
0,1585 |
0,9154 |
1,000 |
|
|
|
|
|
|
infiltrators© |
0,0676 |
-0,2086 |
-0,2807 |
0,0369 |
0,105 |
1,000 |
|
|
|
|
|
sucked |
-0,0456 |
0,0425 |
-0,1867 |
0,0566 |
-0,0221 |
0,6273 |
1,000 |
|
|
|
|
flap |
-0,0096 |
-0,112 |
-0,1505 |
-0,1685 |
-0,2203 |
0,3493 |
0,3125 |
1,000 |
|
|
|
â??Hb |
0,1282 |
0,5463 |
0,5357 |
-0,5402 |
-0,5204 |
-0,1739 |
0,0592 |
0,0461 |
1,000 |
|
|
â??Hto |
0,0385 |
0,4434 |
0,6327 |
-0,5193 |
-0,562 |
-0,2296 |
-0,0916 |
-0,0424 |
0,8198 |
1,000 |
Table 4: Spearman.excel correlation
Summary of Results
Based on the results previously presented, it can be seen that there are statistically significant differences between hemoglobin and hematocrit before and after surgery, since the p value is less than 0.05 in the Wilcoxon test. This means that post-surgical Hb and Ht show a significant reduction compared to pre-surgical hemoglobin and hematocrit. This result is expected, since liposuction inevitably sucks blood. Despite a reduction in hemoglobin and hematocrit, no patient required a red blood cell transfusion after surgery or had hemoglobin below 8 g / dl. These parameters are important, since they were the objectives that were sought to be achieved with the application of tranexamic acid.
On the other hand, a Spearman correlation was made between post-surgical hemoglobin and suctioned fluids, which was 0.056. This means that there is no direct correlation between these variables. Likewise, a correlation was made between the post-surgical hematocrit and the suctioned fluids, which was -0.022, so there is no association and a correlation between the hemoglobin delta and the sucked fluids, which was 0.05, so neither there was association.
Age was also not correlated with post-surgical hemoglobin, since it presents an index of -0.23, so there was no association.
Finally, it was decided to make a correlation between the weight of the flap and other study variables. The correlation between flap weight and post-surgical hemoglobin was -0.16, so there was no association. Similarly, a correlation was made between the weight of the flap and the hemoglobin delta, which had a coefficient of 0.046, so there was no association.
Previous evidence
Although the evidence on the use of tranexamic acid in plastic surgery is scarce [7-9], interesting studies can be found on this topic. In 2018 in Rio de Janeiro, Brazil, Consanção et al [5] carried out a prospective study in which they wanted to evaluate the effects of tranexamic acid in reducing perioperative bleeding in patients who were going to undergo liposuction. For this, the author divided a group of women into 2 cohorts, one experimental to which 10 mg of tranexamic acid was applied prior to liposuction and another control cohort that received 0.9% saline solution only. After surgery, a comparison was made of the hematocrit levels and the amount of blood in the volume of lipoaspirate. In the end, it was concluded that the experimental group to which tranexamic acid was applied presented higher levels of postoperative hematocrit, less reduction in hematocrit with respect to the initial values and lower blood volume in liposuction.
The study mentioned above is very useful as it has similar features to the study outlined in this article. The Consanção study population has characteristics similar to the population in our study, since they are women who undergo liposuction. Additionally, in both studies hematocrit was used as a measure to define postoperative bleeding.
Despite the similarities mentioned, the Consanção study has important differences with respect to our study. The main difference is that Consanção's research used a control group and an experimental group, which allowed him to compare the results of both groups. In contrast, our study only seeks to report a series of cases and a controlled clinical study was not carried out. On the other hand, Consanção used the Klein equation to determine the total volume of blood in the lipoaspirate, while this variable was not taken into account in our study.
Implications for research
The objective of the research that was carried out is to establish the basis for further research to expand the knowledge on the use of tranexamic acid in cosmetic surgery. We consider that with the findings presented in this study, investigations involving a larger population or experimental and control groups can be carried out, since this type of study would have greater statistical and epidemiological value.
Implications for practice
The results presented previously are intended to provide health professionals with another possibility in the management of postoperative bleeding in cosmetic procedures. As previously mentioned, controlling bleeding during surgery could ensure a postoperative period with fewer complications and greater patient satisfaction.
It is important to clarify that the study only considers one management possibility.
Finally, it is considered that tranexamic acid presents incipient beneficial results for the management of perioperative bleeding during abdominoplasty plus liposuction. These results serve as the basis for conducting studies with greater methodological rigor on the effects of this drug in body cosmetic surgery.